13188819888

YDE700/500_operating_lamp
 

YDE700/500  operating lamp

 

Main technical parameters:

 

Performance

Units

700 lamp head

500 lamp head

Illumination

Lux

 160000

 120000

Temperature

K

3000-6700

3000-6700

Color rendering index Ra

 

 95

 95

Light depth

mm

1000

1000

Wavelength small 400nm irradiance

W/

 0.006

 0.006

Focus adjustment

 

Manual

Manual

Number of lamp beads 

PCS 

80PCS, 24V/1W

48PCS, 24V/1W

Power supply

 

220V  50Hz

220V  50Hz

Input power

W

100

80

Average LED life

H

100000

100000

Minimum mounting height

M

2.8

2.8

 

Product advantages and features:

1. Color temperature adjustment: the lamp holder is installed with different color temperature "OSram" LED lamp beads, in the case of maintaining the color rendering index 85, the color temperature is adjusted between 3000K and 6700K; Thus achieving the best tissue resolution.

2. Bright and uniform lighting: the beam emitted by the LED light source is focused through a specially designed high-performance lens in the surgical area to meet the optical domain required for surgical lighting; The maximum illumination can reach 160.000LUX. The brightness of the LED is stepless controlled by digital means, and the illumination of each lamp head can be adjusted separately; .

3. Extremely low failure rate: each LED module contains 6-10 LED lamp beads, each module contains an independent electronic control system, the lamp head has a very low failure rate, the failure of a single LED will not affect the function of the lamp head.

4. Convenient focal length adjustment: with manual focusing system can achieve bright and uniform shadowless lighting effect, in the spot adjustment range can reach the maximum illuminance, not only to meet the requirements of large open surgery large spot high illuminance requirements, but also to meet the requirements of small spot high illuminance required by conventional window surgery;

5. Low heat production: The greater advantage of LED is that it produces less heat, because it almost does not emit infrared or ultraviolet light.

6. Average service life: LED lights are superior to traditional halogen or gas lamps in that they have a long service life. Conventional lights usually have to be replaced after 600 to 5,000 hours of use, and the average life of LED lights is 100,000 hours.

7. Energy saving: Using 1W lamp beads using 3D software to simulate the spatial position, with the least arrangement of lamp beads to complete the established performance indicators;

8. In line with the laminar flow turbulence design, so that the purified laminar flow air can easily move with the streamline of the surgical lamp, and so that the lamp can maintain a better working temperature, effectively ensure the service life of the LED lamp beads.

9. Luxury spring arm, durable, light and flexible. The lamp holder can be easily rotated 360° and accurately positioned in the ideal position. The lamp arm has a wide range of activity and can be applied to the operating room under different building conditions.

10. Detachable handle jacket, can be disinfected at 135℃, can operate the focus, position and Angle of the lamp body;

 

Working environment conditions:

1) Ambient temperature +10 - +40℃;

2) relative humidity 30% ~ 75%;

3) atmospheric pressure (500 ~ 1060) hPa;

4) Power supply voltage and frequency AC 220V±22V  50HZ±10HZ;